Thiết bị bù công suất phản kháng động điện áp cao (SVG)

Thiết bị bù công suất phản kháng động điện áp cao (SVG)

High voltage SVG reactive power compensation system with IGBT power modules. Provides capacitive or inductive reactive power according to the selected control mode, with monitoring and communication options defined for the project.
Nhận báo giá nhanh chóng






    Tổng quan về sản phẩm

    The high voltage SVG reactive power compensation device uses IGBT power modules to provide capacitive or inductive reactive power. It supports voltage and reactive power control for distribution networks and industrial electrical systems. The required compensation capacity and control settings depend on the actual load profile.

    Reactive power compensation for changing loads

    First, review the site voltage, load changes and power factor requirements. Then define the compensation range and the point where the system will measure electrical quantities. This helps match the equipment to the operating conditions and the project objectives.

    The existing design includes a chain inverter with multiple series-connected modules in each phase. Module redundancy and the control arrangement follow the selected configuration. Confirm the required performance through the offered data sheet and project review.

    Features & Options

    Power modules and control

    • IGBT-based modular circuit with N+1 or N+2 redundancy options as specified.
    • FPGA module control and fiber-optic links between the power modules and main control system.
    • Self-excitation startup arrangement to limit inrush current.
    • System or load compensation modes, with settings matched to the application.

    Monitoring and communication

    The listed local monitoring arrangement uses DSP and PLC control with a touch-screen interface. Displayed information includes module DC voltage, module fault or bypass status, current values, fault history and output current waveforms.

    Ethernet, RS485 and CAN interfaces are listed for communication. Confirm the supported protocol and connection to the site monitoring system. The existing interface description specifies Chinese text; agree any required display language before ordering.

    Parallel control power modules and DC UPS backup are available as configuration options. Confirm backup scope and operating duration for the project.

    Selection & Configuration

    System voltage and frequency To be confirmed from the site supply
    Compensation capacity Selected from load data and compensation requirements
    Power circuit IGBT-based chain inverter
    Control mode System or load compensation, as configured
    Communication interfaces Ethernet, RS485 and CAN as specified
    Control power backup Optional DC UPS arrangement

    Confirm response performance, cooling, enclosure dimensions and site conditions in the approved technical specification.

    Quotation & Related Products

    Request a reactive power compensation quotation

    Send the single-line diagram, supply voltage, load profile and required compensation capacity. Also include any power quality measurements, installation space and monitoring requirements. State the desired power factor and other performance targets for technical review.

    Email Kathy at kathy@nbhh-group.com with your project information. For related distribution equipment, see our low voltage power distribution cabinet hoặc gas insulated switchgear.

    Bạn đang lên kế hoạch cho một dự án phân phối điện hoặc năng lượng tái tạo?

    Nhận hỗ trợ kỹ thuật và báo giá tùy chỉnh

    • Hơn 15 năm kinh nghiệm trong ngành
    • Dòng sản phẩm đầy đủ về kết nối lưới điện và bù đắp
    • Phục vụ khách hàng tại hơn 30 quốc gia
    • Hơn 100 quyền sở hữu trí tuệ
    • 12% Doanh thu hàng năm được tái đầu tư vào nghiên cứu và phát triển (R&D) và đổi mới.
    • Hỗ trợ kỹ thuật toàn diện và thiết kế kỹ thuật tùy chỉnh

    Yêu cầu báo giá

      viTiếng Việt