Dispositivo de compensação de potência reactiva dinâmica de alta tensão (SVG)

Dispositivo de compensação de potência reactiva dinâmica de alta tensão (SVG)

High voltage SVG reactive power compensation system with IGBT power modules. Provides capacitive or inductive reactive power according to the selected control mode, with monitoring and communication options defined for the project.
Obter um orçamento rápido






    Visão geral do produto

    The high voltage SVG reactive power compensation device uses IGBT power modules to provide capacitive or inductive reactive power. It supports voltage and reactive power control for distribution networks and industrial electrical systems. The required compensation capacity and control settings depend on the actual load profile.

    Reactive power compensation for changing loads

    First, review the site voltage, load changes and power factor requirements. Then define the compensation range and the point where the system will measure electrical quantities. This helps match the equipment to the operating conditions and the project objectives.

    The existing design includes a chain inverter with multiple series-connected modules in each phase. Module redundancy and the control arrangement follow the selected configuration. Confirm the required performance through the offered data sheet and project review.

    Características e opções

    Power modules and control

    • IGBT-based modular circuit with N+1 or N+2 redundancy options as specified.
    • FPGA module control and fiber-optic links between the power modules and main control system.
    • Self-excitation startup arrangement to limit inrush current.
    • System or load compensation modes, with settings matched to the application.

    Monitoring and communication

    The listed local monitoring arrangement uses DSP and PLC control with a touch-screen interface. Displayed information includes module DC voltage, module fault or bypass status, current values, fault history and output current waveforms.

    Ethernet, RS485 and CAN interfaces are listed for communication. Confirm the supported protocol and connection to the site monitoring system. The existing interface description specifies Chinese text; agree any required display language before ordering.

    Parallel control power modules and DC UPS backup are available as configuration options. Confirm backup scope and operating duration for the project.

    Seleção e configuração

    System voltage and frequency To be confirmed from the site supply
    Compensation capacity Selected from load data and compensation requirements
    Power circuit IGBT-based chain inverter
    Control mode System or load compensation, as configured
    Communication interfaces Ethernet, RS485 and CAN as specified
    Control power backup Optional DC UPS arrangement

    Confirm response performance, cooling, enclosure dimensions and site conditions in the approved technical specification.

    Orçamento e produtos relacionados

    Request a reactive power compensation quotation

    Send the single-line diagram, supply voltage, load profile and required compensation capacity. Also include any power quality measurements, installation space and monitoring requirements. State the desired power factor and other performance targets for technical review.

    Email Kathy em kathy@nbhh-group.com with your project information. For related distribution equipment, see our armário de distribuição de energia de baixa tensão ou aparelhagem de comutação isolada a gás.

    Está a planear um projeto de distribuição de energia ou de energias renováveis?

    Obtenha assistência técnica e um orçamento personalizado

    • Mais de 15 anos de experiência no setor
    • Gama completa de produtos de ligação à rede e de compensação
    • A atender clientes em mais de 30 países
    • Mais de 100 direitos de propriedade intelectual
    • 12% Receitas anuais reinvestidas em I&D Inovação
    • Suporte técnico de ciclo completo e engenharia personalizada

    Obter um orçamento

      pt_PTPortuguês