Perangkat Kompensasi Daya Reaktif Dinamis Tegangan Tinggi (SVG)

Perangkat Kompensasi Daya Reaktif Dinamis Tegangan Tinggi (SVG)

High voltage SVG reactive power compensation system with IGBT power modules. Provides capacitive or inductive reactive power according to the selected control mode, with monitoring and communication options defined for the project.
Dapatkan Penawaran Cepat






    Gambaran Umum Produk

    The high voltage SVG reactive power compensation device uses IGBT power modules to provide capacitive or inductive reactive power. It supports voltage and reactive power control for distribution networks and industrial electrical systems. The required compensation capacity and control settings depend on the actual load profile.

    Reactive power compensation for changing loads

    First, review the site voltage, load changes and power factor requirements. Then define the compensation range and the point where the system will measure electrical quantities. This helps match the equipment to the operating conditions and the project objectives.

    The existing design includes a chain inverter with multiple series-connected modules in each phase. Module redundancy and the control arrangement follow the selected configuration. Confirm the required performance through the offered data sheet and project review.

    Features & Options

    Power modules and control

    • IGBT-based modular circuit with N+1 or N+2 redundancy options as specified.
    • FPGA module control and fiber-optic links between the power modules and main control system.
    • Self-excitation startup arrangement to limit inrush current.
    • System or load compensation modes, with settings matched to the application.

    Monitoring and communication

    The listed local monitoring arrangement uses DSP and PLC control with a touch-screen interface. Displayed information includes module DC voltage, module fault or bypass status, current values, fault history and output current waveforms.

    Ethernet, RS485 and CAN interfaces are listed for communication. Confirm the supported protocol and connection to the site monitoring system. The existing interface description specifies Chinese text; agree any required display language before ordering.

    Parallel control power modules and DC UPS backup are available as configuration options. Confirm backup scope and operating duration for the project.

    Selection & Configuration

    System voltage and frequency To be confirmed from the site supply
    Compensation capacity Selected from load data and compensation requirements
    Power circuit IGBT-based chain inverter
    Mode kontrol System or load compensation, as configured
    Communication interfaces Ethernet, RS485 and CAN as specified
    Control power backup Optional DC UPS arrangement

    Confirm response performance, cooling, enclosure dimensions and site conditions in the approved technical specification.

    Quotation & Related Products

    Request a reactive power compensation quotation

    Send the single-line diagram, supply voltage, load profile and required compensation capacity. Also include any power quality measurements, installation space and monitoring requirements. State the desired power factor and other performance targets for technical review.

    Email Kathy at kathy@nbhh-group.com with your project information. For related distribution equipment, see our low voltage power distribution cabinet atau gas insulated switchgear.

    Sedang merencanakan proyek distribusi listrik atau energi terbarukan?

    Dapatkan Dukungan Teknis & Penawaran Harga Khusus

    • Pengalaman di Industri Selama Lebih dari 15 Tahun
    • Rangkaian Lengkap Produk Sambungan Jaringan & Kompensasi
    • Melayani Pelanggan di Lebih dari 30 Negara
    • Lebih dari 100 Hak Kekayaan Intelektual
    • 12% Pendapatan Tahunan Diinvestasikan Kembali dalam Inovasi Litbang
    • Dukungan Teknis Siklus Penuh dan Rekayasa Khusus

    Dapatkan Penawaran

      id_IDBahasa Indonesia