Peralatan Pemutus Arus Berisolasi Gas dalam Wadah Logam (GIS)
Peralatan Pemutus Arus Berisolasi Gas dalam Wadah Logam (GIS)
Ikhtisar
Henghui metal-enclosed gas insulated switchgear (GIS) combines switching, protection and monitoring for electrical distribution projects. The listed design uses low-pressure SF6 as the insulating medium. Vacuum circuit breakers and three-position switches form the main primary components inside a sealed gas compartment.
Typical applications include substation distribution, industrial facilities, commercial buildings and power plant auxiliary systems. The compact arrangement can help projects with limited switchroom space. However, each installation needs a review of its electrical duties, access clearances and service conditions.
Gas insulated switchgear for project requirements
Choose the configuration from an approved single-line diagram. First, confirm the system voltage, rated current and short-circuit duty. Then define the incoming, outgoing and bus section functions. Henghui can review the required arrangement before preparing a project quotation.
Features & Maintenance
Enclosure and switching arrangement
- Sealed primary compartment: A welded stainless steel gas chamber houses the primary components and helps limit exposure to ambient contamination.
- Compact layout: The enclosed arrangement supports installations where floor space is a key design constraint.
- Mechanical interlocks: Interlocking helps prevent incorrect switching sequences. Confirm the exact interlock scheme in the approved drawings.
- Modular configuration: Define the required feeder functions and cabinet arrangement to suit the project.
Site suitability and maintenance
For humid, coastal, polluted or high-altitude sites, provide the actual installation conditions for technical review. The existing product information lists IP67 for the sealed gas chamber. Confirm that rating in the selected model documentation; it does not describe the complete cabinet or every cable connection.
A sealed gas compartment does not remove the need for inspection and servicing. Follow the supplied operating instructions for gas condition checks, operating mechanisms, interlocks and cable terminations. Only qualified personnel should perform switching and maintenance.
Selection & Configuration
| Selection item | Project information |
|---|---|
| Insulation medium | Low-pressure SF6 in the listed design |
| Main switching components | Vacuum circuit breaker and three-position switch |
| Electrical ratings | Voltage, current, frequency and short-circuit duty to be confirmed |
| Feeder arrangement | Incoming, outgoing and bus section functions per approved diagram |
| Secondary systems | Protection, metering, auxiliary supply and communication requirements to be agreed |
| Site and enclosure | Indoor or outdoor arrangement, altitude, ambient conditions and protection requirements to be reviewed |
Final ratings, dimensions and supply scope follow the confirmed model and approved project documents.
Quotation & Related Products
Request a gas insulated switchgear quotation
Send the single-line diagram, feeder quantity, required ratings and installation location. Also include cable entry direction, room dimensions and any protection or metering preferences. This information helps us define the equipment boundary and prepare a clear offer.
For related equipment, see our X-40.5 series C-GIS cabinet atau modular substation. Each product has its own configuration and rating requirements.
Contact Kathy at kathy@nbhh-group.com to discuss your drawings and quotation requirements.