- Pengalaman di Industri Selama Lebih dari 15 Tahun
- Rangkaian Lengkap Produk Sambungan Jaringan & Kompensasi
- Melayani Pelanggan di Lebih dari 30 Negara
- Lebih dari 100 Hak Kekayaan Intelektual
- 12% Pendapatan Tahunan Diinvestasikan Kembali dalam Inovasi Litbang
- Dukungan Teknis Siklus Penuh dan Rekayasa Khusus
Trafo Tipe Kering Berbahan Resin Cor 10 kV
Trafo Tipe Kering Berbahan Resin Cor 10 kV
Gambaran Umum Produk
Trafo Tipe Kering Berbahan Resin Cor 10 kV
Yang Trafo tipe kering berisolasi resin 10 kV family includes SCB13 and SCB14 series units for distribution projects. The listed capacity range is 30–2500 kVA. Henghui reviews the required voltage ratio and site conditions before confirming a configuration.
The cast-resin winding assembly provides a dry-type construction. However, the complete installation still needs suitable ventilation, access and environmental protection. An enclosure and temperature monitoring can form part of the agreed order.
For example, a building installation may have limits on available space and ventilation. Therefore, share the room layout as well as the electrical ratings during selection.
Spesifikasi Teknis
| Series | SCB13 / SCB14 |
|---|---|
| Voltage class | 10 kV; exact ratio to project requirements |
| Rated capacity | 30–2500 kVA |
| Construction | Cast-resin dry-type |
| Cooling | AN / AF, depending on configuration |
| Insulation class | F / H, as specified |
Typical product-family information. Final ratings, losses, dimensions and enclosure suitability follow the approved technical specification.
Applications & Quotation
Applications and Installation Review
Typical applications include commercial buildings, industrial facilities and packaged substations where the electrical design specifies a dry-type transformer.
First, confirm the required load capacity and primary and secondary voltages. Next, review the ambient conditions, cooling arrangement and enclosure. Also, check terminal access and the route for moving the transformer into position.
Natural or forced-air cooling depends on the configuration. Consequently, any rating associated with a cooling mode must match the selected data sheet. The family capacity range does not guarantee every combination of rating and enclosure.
Quotation Checklist
Request a Dry-Type Transformer Quote
Untuk sebuah Trafo tipe kering berisolasi resin 10 kV quotation, provide:
- Required capacity and HV/LV voltage ratio
- Frequency, vector group, impedance and tapping requirements
- Cooling mode and insulation class requirements
- Enclosure rating, room layout and ventilation details
- Altitude, ambient conditions and terminal arrangement
- Quantity, destination and delivery schedule
If some details remain open, identify them clearly. Our team can then state the assumptions in the proposal for your review.
Documentation & Supply Scope
Confirm the Offered Configuration
The quotation defines the selected rating, enclosure, accessories and inspection scope. Also, request the equipment data sheet, dimensions and applicable test documents.
Our team agrees on the final losses, cooling arrangement and installation limits with you before production. Compare these details alongside the price rather than relying on the series name alone.
For a different voltage class, see our 20kV dry-type transformer. Finally, send your transformer requirements or email Kathy: kathy@nbhh-group.com.
Sedang merencanakan proyek distribusi listrik atau energi terbarukan?
Dapatkan Dukungan Teknis & Penawaran Harga Khusus
KIRIMKAN EMAIL KEPADA KAMI





