Transformador de tipo seco con resina moldeada de 10 kV

Transformador de tipo seco con resina moldeada de 10 kV

10kV cast-resin dry-type transformer from the SCB13 / SCB14 family, covering 30–2500 kVA. Cooling, insulation class, enclosure and terminal arrangements follow the approved project specification.
Presupuesto rápido






    Descripción general del producto

    Transformador de tipo seco con resina moldeada de 10 kV

    The Transformador de tipo seco con resina moldeada de 10 kV family includes SCB13 and SCB14 series units for distribution projects. The listed capacity range is 30–2500 kVA. Henghui reviews the required voltage ratio and site conditions before confirming a configuration.

    The cast-resin winding assembly provides a dry-type construction. However, the complete installation still needs suitable ventilation, access and environmental protection. An enclosure and temperature monitoring can form part of the agreed order.

    For example, a building installation may have limits on available space and ventilation. Therefore, share the room layout as well as the electrical ratings during selection.

    Technical Specifications

    Series SCB13 / SCB14
    Voltage class 10 kV; exact ratio to project requirements
    Rated capacity 30–2500 kVA
    Construction Cast-resin dry-type
    Cooling AN / AF, depending on configuration
    Insulation class F / H, as specified

    Typical product-family information. Final ratings, losses, dimensions and enclosure suitability follow the approved technical specification.

    Applications & Quotation

    Applications and Installation Review

    Typical applications include commercial buildings, industrial facilities and packaged substations where the electrical design specifies a dry-type transformer.

    First, confirm the required load capacity and primary and secondary voltages. Next, review the ambient conditions, cooling arrangement and enclosure. Also, check terminal access and the route for moving the transformer into position.

    Natural or forced-air cooling depends on the configuration. Consequently, any rating associated with a cooling mode must match the selected data sheet. The family capacity range does not guarantee every combination of rating and enclosure.

    Quotation Checklist

    Request a Dry-Type Transformer Quote

    For a Transformador de tipo seco con resina moldeada de 10 kV quotation, provide:

    • Required capacity and HV/LV voltage ratio
    • Frequency, vector group, impedance and tapping requirements
    • Cooling mode and insulation class requirements
    • Enclosure rating, room layout and ventilation details
    • Altitude, ambient conditions and terminal arrangement
    • Quantity, destination and delivery schedule

    If some details remain open, identify them clearly. Our team can then state the assumptions in the proposal for your review.

    Documentation & Supply Scope

    Confirm the Offered Configuration

    The quotation defines the selected rating, enclosure, accessories and inspection scope. Also, request the equipment data sheet, dimensions and applicable test documents.

    Our team agrees on the final losses, cooling arrangement and installation limits with you before production. Compare these details alongside the price rather than relying on the series name alone.

    For a different voltage class, see our 20kV dry-type transformer. Finally, send your transformer requirements or email Kathy: kathy@nbhh-group.com.

    ¿Estás planificando un proyecto de distribución eléctrica o de energías renovables?

    Obtén asistencia técnica y un presupuesto personalizado

    • Más de 15 años de experiencia en el sector
    • Gama completa de productos de conexión a red y compensación
    • Atendemos a clientes en más de 30 países
    • Más de 100 derechos de propiedad intelectual
    • 12% Ingresos anuales reinvertidos en I+D Innovación
    • Asistencia técnica de ciclo completo e ingeniería personalizada

    Solicitar presupuesto