- Más de 15 años de experiencia en el sector
- Gama completa de productos de conexión a red y compensación
- Atendemos a clientes en más de 30 países
- Más de 100 derechos de propiedad intelectual
- 12% Ingresos anuales reinvertidos en I+D Innovación
- Asistencia técnica de ciclo completo e ingeniería personalizada
Dispositivo dinámico de compensación de potencia reactiva de alta tensión (SVG)
Dispositivo dinámico de compensación de potencia reactiva de alta tensión (SVG)
Descripción general del producto
The high voltage SVG reactive power compensation device uses IGBT power modules to provide capacitive or inductive reactive power. It supports voltage and reactive power control for distribution networks and industrial electrical systems. The required compensation capacity and control settings depend on the actual load profile.
Reactive power compensation for changing loads
First, review the site voltage, load changes and power factor requirements. Then define the compensation range and the point where the system will measure electrical quantities. This helps match the equipment to the operating conditions and the project objectives.
The existing design includes a chain inverter with multiple series-connected modules in each phase. Module redundancy and the control arrangement follow the selected configuration. Confirm the required performance through the offered data sheet and project review.
Features & Options
Power modules and control
- IGBT-based modular circuit with N+1 or N+2 redundancy options as specified.
- FPGA module control and fiber-optic links between the power modules and main control system.
- Self-excitation startup arrangement to limit inrush current.
- System or load compensation modes, with settings matched to the application.
Monitoring and communication
The listed local monitoring arrangement uses DSP and PLC control with a touch-screen interface. Displayed information includes module DC voltage, module fault or bypass status, current values, fault history and output current waveforms.
Ethernet, RS485 and CAN interfaces are listed for communication. Confirm the supported protocol and connection to the site monitoring system. The existing interface description specifies Chinese text; agree any required display language before ordering.
Parallel control power modules and DC UPS backup are available as configuration options. Confirm backup scope and operating duration for the project.
Selection & Configuration
| System voltage and frequency | To be confirmed from the site supply |
|---|---|
| Compensation capacity | Selected from load data and compensation requirements |
| Power circuit | IGBT-based chain inverter |
| Control mode | System or load compensation, as configured |
| Communication interfaces | Ethernet, RS485 and CAN as specified |
| Control power backup | Optional DC UPS arrangement |
Confirm response performance, cooling, enclosure dimensions and site conditions in the approved technical specification.
Quotation & Related Products
Request a reactive power compensation quotation
Send the single-line diagram, supply voltage, load profile and required compensation capacity. Also include any power quality measurements, installation space and monitoring requirements. State the desired power factor and other performance targets for technical review.
Email Kathy at kathy@nbhh-group.com with your project information. For related distribution equipment, see our low voltage power distribution cabinet or gas insulated switchgear.
¿Estás planificando un proyecto de distribución eléctrica o de energías renovables?
Obtén asistencia técnica y un presupuesto personalizado
ENVÍENOS UN CORREO ELECTRÓNICO