Kabinet Switchgear Berinsulasi Gas Seri X-40.5 SF6

Kabinet Switchgear Berinsulasi Gas Seri X-40.5 SF6

X-40.5 SF6 gas insulated switchgear for 40.5kV three-phase AC, 50Hz distribution systems. Uses vacuum circuit breakers and three-position switches in a sealed stainless steel gas compartment, with project-specific protection and control.
Dapatkan Penawaran Cepat






    Reference Standards

    The following references are retained from the existing product information. Agree the applicable standards, editions and documentation scope during technical review. This list does not establish certification or confirm that every reference applies to every configuration.

    GB/T 1207 Electromagnetic Voltage Transformers
    GB/T 1208 Current Transformers
    GB/T 1984 High-Voltage Ac Circuit Breakers
    GB/T 1985 High-Voltage Ac Disconnectors and Earthing Switches
    GB/T 3906 3.6 kV-40.5 kV Ac Metal-Enclosed Switchgear and control-gear
    GB/T 11022 Common Technical Requirements for High-Voltage Switchgear and Controlgear Standards
    GB 50150 Standard for Electrical Equipment Handover Testing in Electrical Installation Engineering
    DL/T 402 Technical Specifications for Ordering High-Voltage AC Circuit Breakers
    DL/T 404 3.6 kV-40.5 kV AC Metal-Enclosed Switchgear and Controlgear
    DL/T 486 High-Voltage Ac Disconnectors and Earthing Switches
    DL/T 593 Common Technical Requirements for High-Voltage Switchgear and Controlgear Standards
    Q/GDW13088.1-2018 12 kV~40.5 kV High-Voltage Switchgear Procurement Standard, Part 1: General Technical Specification
    Q/GDW13088.16-2018 12 kV-40.5 kV High-Voltage Switchgear Procure-ment Standard, Part 16:Technical Specification for 40.5 kV/1250 A-31.5 kA Gas-Insulated High-Voltage Switchgear

    Product Overview & Model

    The X-40.5 SF6 gas insulated switchgear uses low-pressure SF6 as its insulating medium. Vacuum circuit breakers and three-position switches form the main primary components. A sealed gas compartment made from 3mm stainless steel houses these components in the listed design.

    SF6 gas insulated switchgear applications

    This assembly serves 40.5kV three-phase AC, 50Hz single-busbar and sectionalized single-busbar systems. Typical applications include substations, industrial distribution and generation facilities. Confirm motor-switching duties separately where the project includes high-voltage motors.

    First, define the incoming and outgoing feeder functions. Then review rated current, short-circuit duties, control supply and cable connections. The compact arrangement supports projects where switchroom space is limited, subject to the approved layout and access requirements.

    The existing product information describes high-altitude applications up to 5500m. Confirm the actual altitude and environmental conditions for the selected configuration. A sealed compartment still requires the inspections and servicing defined in the operating instructions.

    Model reference

    X-40.5 SF6 gas insulated switchgear model designation

    The model illustration is a reference. Confirm the complete designation and offered ratings in the quotation.

    Cabinet Layout

    Cabinet interior layout

    1. Main switch mechanism
    2. Isolating mechanism
    3. Cable compartment
    4. Secondary control box
    5. Busbar connection bushing
    6. Disconnector
    7. Arc-extinguishing device
    8. Enclosed cabinet body
    9. Internal pressure-relief device

    X-40.5 switchgear cabinet interior arrangement

     

    Illustration of Core Components

    SF6 gas insulated switchgear core components

    Technical Parameter Table

    The existing parameter image below describes the product family. Confirm the rated current, short-circuit duty, insulation levels and other performance requirements for the offered configuration. Final values follow the agreed equipment data sheet.

    X-40.5 SF6 gas insulated switchgear technical parameter reference

    Typical Schemes

    Main Primary Typical Schemes

    X-40.5 switchgear typical primary circuit schemes

    Installation Dimension Table

    Rated Current (A) 1250 2500 3150
    Cabinet Width (mm) 600 800 1000

    Technical Requirements

    L Cabinet Width (mm) 600 800 1000
    L1 Base Mounting Hole (mm) 430 630 830
    1. The switchgear can be bolted or welded to the foundation channel steel.
    2. The installation of the foundation channel steel must ensure flatness, with unevenness not exceeding 1 mm per meter.
    3. The foundation should be capable of bearing a maximum static load of 2000 kg and a maximum impact load of 3000 kg from the switchgear.

    These scheme and installation dimensions are references. Confirm the selected feeder arrangement, foundation loads and mounting details against the approved project drawings.

    Quotation & Related Products

    Request an SF6 gas insulated switchgear quotation

    Send your single-line diagram, panel quantities and electrical ratings to Kathy at kathy@nbhh-group.com. Include the auxiliary supply, protection and metering requirements, cable details, altitude and available space.

    Also state the required standards, test documents and delivery destination. For related equipment, see our metal-enclosed GIS atau KYN61-40.5 switchgear.

    Sedang merencanakan proyek distribusi listrik atau energi terbarukan?

    Dapatkan Dukungan Teknis & Penawaran Harga Khusus

    • Pengalaman di Industri Selama Lebih dari 15 Tahun
    • Rangkaian Lengkap Produk Sambungan Jaringan & Kompensasi
    • Melayani Pelanggan di Lebih dari 30 Negara
    • Lebih dari 100 Hak Kekayaan Intelektual
    • 12% Pendapatan Tahunan Diinvestasikan Kembali dalam Inovasi Litbang
    • Dukungan Teknis Siklus Penuh dan Rekayasa Khusus

    Dapatkan Penawaran