X-40.5 Series SF6 Gas Insulated Switchgear Cabinet
X-40.5 Series SF6 Gas Insulated Switchgear Cabinet
Reference Standards
The following references are retained from the existing product information. Agree the applicable standards, editions and documentation scope during technical review. This list does not establish certification or confirm that every reference applies to every configuration.
| GB/T 1207 | Electromagnetic Voltage Transformers |
| GB/T 1208 | Current Transformers |
| GB/T 1984 | High-Voltage Ac Circuit Breakers |
| GB/T 1985 | High-Voltage Ac Disconnectors and Earthing Switches |
| GB/T 3906 | 3.6 kV-40.5 kV Ac Metal-Enclosed Switchgear and control-gear |
| GB/T 11022 | Common Technical Requirements for High-Voltage Switchgear and Controlgear Standards |
| GB 50150 | Standard for Electrical Equipment Handover Testing in Electrical Installation Engineering |
| DL/T 402 | Technical Specifications for Ordering High-Voltage AC Circuit Breakers |
| DL/T 404 | 3.6 kV-40.5 kV AC Metal-Enclosed Switchgear and Controlgear |
| DL/T 486 | High-Voltage Ac Disconnectors and Earthing Switches |
| DL/T 593 | Common Technical Requirements for High-Voltage Switchgear and Controlgear Standards |
| Q/GDW13088.1-2018 | 12 kV~40.5 kV High-Voltage Switchgear Procurement Standard, Part 1: General Technical Specification |
| Q/GDW13088.16-2018 | 12 kV-40.5 kV High-Voltage Switchgear Procure-ment Standard, Part 16:Technical Specification for 40.5 kV/1250 A-31.5 kA Gas-Insulated High-Voltage Switchgear |
Product Overview & Model
The X-40.5 SF6 gas insulated switchgear uses low-pressure SF6 as its insulating medium. Vacuum circuit breakers and three-position switches form the main primary components. A sealed gas compartment made from 3mm stainless steel houses these components in the listed design.
SF6 gas insulated switchgear applications
This assembly serves 40.5kV three-phase AC, 50Hz single-busbar and sectionalized single-busbar systems. Typical applications include substations, industrial distribution and generation facilities. Confirm motor-switching duties separately where the project includes high-voltage motors.
First, define the incoming and outgoing feeder functions. Then review rated current, short-circuit duties, control supply and cable connections. The compact arrangement supports projects where switchroom space is limited, subject to the approved layout and access requirements.
The existing product information describes high-altitude applications up to 5500m. Confirm the actual altitude and environmental conditions for the selected configuration. A sealed compartment still requires the inspections and servicing defined in the operating instructions.
Model reference

The model illustration is a reference. Confirm the complete designation and offered ratings in the quotation.
Cabinet Layout
Cabinet interior layout
- Main switch mechanism
- Isolating mechanism
- Cable compartment
- Secondary control box
- Busbar connection bushing
- Disconnector
- Arc-extinguishing device
- Enclosed cabinet body
- Internal pressure-relief device

Illustration of Core Components

Technical Parameter Table
The existing parameter image below describes the product family. Confirm the rated current, short-circuit duty, insulation levels and other performance requirements for the offered configuration. Final values follow the agreed equipment data sheet.

Typical Schemes
Main Primary Typical Schemes

Installation Dimension Table
| Rated Current (A) | 1250 | 2500 | 3150 |
| Cabinet Width (mm) | 600 | 800 | 1000 |
Technical Requirements
| L Cabinet Width (mm) | 600 | 800 | 1000 |
| L1 Base Mounting Hole (mm) | 430 | 630 | 830 |
- The switchgear can be bolted or welded to the foundation channel steel.
- The installation of the foundation channel steel must ensure flatness, with unevenness not exceeding 1 mm per meter.
- The foundation should be capable of bearing a maximum static load of 2000 kg and a maximum impact load of 3000 kg from the switchgear.
These scheme and installation dimensions are references. Confirm the selected feeder arrangement, foundation loads and mounting details against the approved project drawings.
Quotation & Related Products
Request an SF6 gas insulated switchgear quotation
Send your single-line diagram, panel quantities and electrical ratings to Kathy at kathy@nbhh-group.com. Include the auxiliary supply, protection and metering requirements, cable details, altitude and available space.
Also state the required standards, test documents and delivery destination. For related equipment, see our metal-enclosed GIS or KYN61-40.5 switchgear.