KYN28-24 Metal-Enclosed Switchgear
KYN28-24 Metal-Enclosed Switchgear
Product Overview
KYN28-24 switchgear serves three-phase power reception and distribution applications. The existing product information describes applications from 10kV to 24kV in substations, power plants and industrial facilities. Confirm the offered rated voltage and electrical duties for the selected configuration.
KYN28-24 switchgear applications
The assembly provides switching, protection and circuit monitoring according to the project scheme. It can also serve high-voltage motor applications when the selected equipment meets the starting and switching duties. First, define the circuit functions. Then confirm the ratings, protection and control requirements.
The cabinet separates the circuit breaker truck, busbar, cable, and relay or instrument sections. An assembled enclosure made from aluminum-zinc-coated steel supports the compartment arrangement. Access and equipment replacement follow the supplied operating procedures.
Features & Options
Compartment layout and interlocks
- Four functional compartments for the breaker truck, busbars, cables and secondary equipment.
- Pressure-relief devices above the compartments in the listed construction.
- Interchangeable trucks of the same specified type and rating, subject to compatibility checks.
- Mechanical interlocks to help prevent incorrect operating sequences.
- Optional electric operation and monitoring components as specified.
Protection and performance confirmation
The existing description lists IP4X enclosure protection and IP2X with a compartment door open. Confirm the exact compartment and operating condition in the offered documentation. Interlocks and enclosure ratings do not replace the required site isolation procedures.
Any internal arc classification or seismic performance must match the selected model and supporting test records. Confirm the classification, current, duration and installation conditions during technical review.
Selection & Configuration
| Application voltage range listed | 10–24kV; confirm the offered rated voltage |
|---|---|
| Rated current options | 630–2500A, according to configuration |
| Short-circuit breaking current options | 20, 25 or 31.5kA |
| Auxiliary control supply | 110V or 220V AC/DC as specified |
| Common dimensions listed | 800 × 1810 × 2380mm or 1000 × 1810 × 2380mm |
| Listed weight range | 840–1440kg, depending on configuration |
The listed ranges describe product options. Final ratings, dimensions, cable arrangement and weight follow the approved drawings and equipment data sheet.
Quotation & Related Products
Request a KYN28-24 switchgear quotation
Send your single-line diagram, panel quantities and electrical ratings to Kathy at kathy@nbhh-group.com. Include the short-circuit duty, auxiliary supply, cable details and site conditions. Also state the required protection, metering and inspection documents.
Compare related products such as our KYN61-40.5 switchgear and gas insulated switchgear. Select the equipment family that matches the approved voltage class and project design.